Understanding and Applying HHSRS Baseline Indicators

Uncategorized
Wishlist Share

About Course

The 2026 reform of the Housing Health and Safety Rating System brought something new: 80 baseline indicators that describe, in plain building terms, what a home should provide. They came into force with the new system on 23 June 2026. They are not minimum standards, and they do not replace the risk assessment. However, they now sit at the heart of how a home is looked at, recorded and put right.

This course shows you how to use them properly. It works through all 19 areas, from structure and drainage to fire safety. It explains what each indicator asks for, how to check it on a visit, and how a finding links to the 21 hazards. The whole way through, you follow one home: Flat B, 27 Fernhill Road, a maisonette in a converted 1930s house. By the end you will have walked it room by room, recorded all 80 indicators, read the findings hazard by hazard, and turned them into a report and an action plan that claim no more than the evidence shows.

It is written for landlords, letting and managing agents, surveyors and housing officers: anyone who needs to look at a home against the 2026 guidance and record what they find in a way others can rely on.

Developed and signed off by a Chartered Environmental Health Practitioner.

Twelve modules and an introduction: 47 narrated video lessons (3 hours 14 minutes) and a short knowledge check after each teaching module, about 5 and a half hours in all. Optional extras, for anyone who wants to go further: five workbook activities, a capstone in which you build Flat B’s full record and action plan, and a final assessment.

This course covers the HHSRS as it applies in England.



Show More

What Will You Learn?

  • Define a baseline indicator, a deficiency, a hazard and a relevant matter in the words of the 2026 guidance, and explain why failing an indicator is a deficiency but not, by itself, a hazard.
  • Prepare for a visit, and record each relevant indicator as met, not met, not applicable or not observed, with the evidence and any gap.
  • Check every area of a home against its indicators, including the measured figures: hot water at 45°C at bath taps and shower heads, 1900 mm headroom, 250 mm of loft insulation, the 5% mould figure and window restrictors under 100 mm.
  • Tell an indicator apart from a separate legal duty, such as gas safety, electrical safety, and smoke and carbon monoxide alarms.
  • Know when a finding needs a specialist, from a structural engineer or asbestos surveyor to a drainage contractor or a trained HHSRS assessor.
  • Map deficiencies to the hazards they bear on, using the hazard profiles, without scoring them.
  • Use Appendix 2 to identify the grade and category of fire detection a dwelling should have.
  • Write a report and an action plan that make no claim of compliance and that someone else can rely on.

Course Content

Course Introduction
How the course works: who it is for, what it will and will not ask of you, the running case and the route through the twelve modules.

Module 1: What baseline indicators are
The definitions everything else rests on: baseline indicator, deficiency, hazard and relevant matters; what the indicators are not; and how the 80 indicators in 19 areas connect to the 21 hazards.

Module 2: Using them on a visit
How to use the indicators in practice, for a landlord or agent checking their own property and for an officer starting an inspection: preparing, looking at the whole dwelling, recording what you find and deciding the next step.

Module 3: Structure, drainage and plumbing
Areas 1 to 3: structural condition, asbestos, drainage, and the water supply including hot water temperatures.

Module 4: Bathroom and kitchen
Areas 4 and 5, the two fullest areas in Appendix 1: the bathroom and WC, and the kitchen, including surfaces, ventilation, cooking and food storage.

Module 5: Drying, space, doors and external space
Areas 6 to 9: clothes drying, space and sleeping rooms, internal doors, and the external space around the dwelling.

Module 6: Noise and security
Areas 10 and 11: noise and sound insulation, and the security of doors, windows, lighting and common entrances.

Module 7: Walking surfaces and guards
Areas 12 and 13: stairs, coverings, handrails, headroom and landings, then guarding, window restrictors and fireguards.

Module 8: Lighting, services, heating and insulation
Areas 14 and 15: lighting, electrical and gas services and sockets, then insulation, heating, combustion appliances and carbon monoxide.

Module 9: Ventilation, moisture and pests
Areas 16 to 18: ventilation, moisture and contaminant control including damp and mould, radon and biocides, and pest management.

Module 10: Fire safety
Area 19: furniture and equipment, gas and electrical safety records, smoke and fire detection (with Appendix 2 on alarm grades and categories), and means of escape.

Module 11: Indicators in assessment and works
Why the indicators matter once a hazard is assessed: how failed indicators bear on the likelihood and harm outcome judgements, how they carry into a schedule of works, and what makes the inspection record built around them stand up when someone else relies on it.

Module 12: Putting it together
The whole of Flat B, 27 Fernhill Road, area by area; the same findings seen hazard by hazard; reporting without claiming compliance; and the action plan.

Student Ratings & Reviews

No Review Yet
No Review Yet

Want to receive push notifications for all major on-site activities?

✕